Product Introduction
Developed by the Dutch microLAN companyTOXmini portable water quality comprehensive toxicity monitorIt is a portable, very simple to operate toxicity detector, and it has a wide range of applications.It can be automatically determined by automatically determining the effect of toxic substances in water media on Vitiligo Fischer, and then judge whether the water media is toxic.
TOXmini can be used in laboratories. Because it is equipped with rechargeable batteries, it can also be used in the field. When used in the field, it can optionally be equipped with a cooling module that maintains the constant temperature of the reaction liquid during the test, so that the test process is fully consistent with theISO11348 standard, thus ensuring the reliability of test results.Because TOXmini and iTOXControl use the same strains and reagents, they can be used in combination with iTOXControl to achieve mutual verification and supplementation effects (the same freeze-dried powder Vibrio Fischer, blank test solution and positive control solution)).
Fashion, flexibility and ease of operation
UCan be plugged in directly or tested with a battery UHigh resolution display UUser operation language: English or German U9-pin RS232 interface can be connected to the computer and transmit data UAdjustable response and test time for better operational flexibility UThe instrument itself can save 2,000 sets of test data.In historical data management, historical data can be checked or deleted by defining the time, location, water sample number, etc. of different water sample tests. UA toxicity baseline can be produced by past historical databases to judge the results of current tests U6 independent test templates, users can define the parameters during the test process by themselves <bio to小-S>model: Only measure the luminescence value after contact reaction between the reference water sample and the water sample to be tested, compare them to obtain the test mode of water sample toxicity results <bio to小-B>model: The initial luminescence value of the reference water sample and the water sample to be tested and the luminescence value after contact reaction is measured to obtain the test mode of water sample toxicity results <RL U>model: Test mode for testing biofluorescent luminescence intensity in water medium in units of luminescence intensity (RLU) (such as ATP or related tests for genetic diagnosis and analysis) |
Application areas
UCan be used for water intake protection of tap water companies UDetection in wastewater treatment engineering: Determine the toxicity value before and after wastewater treatment, and monitor its treatment process and effect. UTesting and monitoring of food water safety for HACCP UIt can be verified and determined with the iTOXcontrol measurement results UThe activity of Vitiligo Fischer can be determined UIt can be compared with the iTOXcontrol measurement results UMake a judgment on the QA/QC of the luminescent bacteria itself USome other toxicity testing applications |
Technical parameters