Seaguard II DCP Doppler Flow Profile
Date:2017-03-21 14:19:18

Seaguard II DCP多普勒流速剖面仪_副本.jpg

Seaguard II DCP is a brand new Seaguard series acoustic flow rate profiler.It creatively improves the acoustic profile capability and further improves the ability of the anchor system to collect high-quality current data when moving and tilting.
It can be used for self-casual measurements or real-time online monitoring, which can meet the different measurement needs of users.SeaGuardII is an intelligent data acquisition and control center, which is composed of SeaGuard electronics and Andra's advanced management software SmartGuard.
Seaguard II DCP operates at 600kHz, and the equipment can measure sea currents at the same time, and measure water quality with multiple parameters.In order to cope with the special requirements of marine upper environmental monitoring, many innovations have been made in product design, such as extending the layout time and optimizing the flexibility of configuration.
The device can be equipped with a number of different Aanderaa smart sensors such as temperature, pressure, conductivity, dissolved oxygen, waves, tides and turbidity.Seaguard II has four analog interfaces and two serial interfaces for external power supply and real-time data transmission.


application

1. Float installation

2. Ocean Sensor Chain Observation Station

3. Water Conservancy Measurement System

4. Base installation

5. Anchor system observation, inverted measurement

6. Multi-parameter ocean observatory

7. One device can be connected to two flow rate sensors at the same time




Unique scalable platform for easy and easy connection to additional sensors

1. Additional sensors can be added, such as: waves, tides, temperature, conductivity, pressure, dissolved oxygen, turbidity, ORP, pH, total algae, etc.


2. It can be easily expanded into an efficient multi-parameter ocean observatory


3. Install two transducers on the same device to double the range


4. A single point flow rate sensor can be installed in the blind spot or boundary layer.


5. LED indicator light, the equipment condition can be visible



Excellent environmental interference compensation function

1. Dynamic motion compensation correction is performed on the data for each pulse measurement


2. Advanced layer adjustment tilt compensation algorithm to obtain real horizontal flow measurements



Best flexibility

1. Narrowband and broadband modes are available to meet different application needs


2. Using one device can solve multiple application needs, and three different profile configurations can be performed simultaneously.


3. Surface measurement function, which can measure sea currents with a thickness of the surface centimeter level (pressure probe is required)


4. Surface reference function, the surface is the reference, and the current measurement of each measurement layer maintains a fixed distance from the surface, tracking the changes in water level.



Longer continuous release time

1. The sampling frequency can be continuously distributed for 24 months every 30 minutes.


2. Use broadband technology to consume less power


3. Increased built-in battery capacity


4. The battery can be made by the user



Intelligent data quality control

1. Enhanced data quality control capabilities


2. Automatically label poor quality data, with status reports on each layer


3. User-selectable automatic pulse algorithm; automatically select the best three-beam pulse combination to remove the impact on data due to the energy blocking of an object due to the passing of an object.



Stronger real-time features

1. Support AIS, GOES, pseudo-binary formats


2. Independent data recording and data sending interval settings


3. Automatically resend lost data



Friendly parameter settings and data analysis interface

1. Set up software before release; real-time data collection software


2. Quick visualization of data post-processing software


3. Automatically resend lost data


技术参数.jpg


Note:
(1) The measurement range is affected by backscattering conditions. For low-scattering waters, the measurement range will be lower than that of high-scattering waters.
(2) Standard deviation of horizontal speed in broadband mode, layer thickness 3m
(3) Pressure sensor 4117 is required
(4) Select the best 3 beams to avoid the impact of occlusion and echo failure
(5) Compensation calibration to ±35°
(6) Alkaline batteries are not recommended for the upper battery compartment because it may cause interference to the meridian.
(7) In broadband mode, 30 minutes sampling interval, 20×2pings, 2m layer thick, 20 layers.
(8) The measurement range can be expanded as required.
(9) Depends on the flow through the conductivity cell.
(10) Multi-point calibration is available: 40 points, at 5 temperatures and 8 oxygen concentrations.
(11) Salinity compensation is required when salinity changes >1mS/cm.
(12) Calibration range 0-120 %.
(13) The serial port can be used as the input interface of the sensor, or as the real-time output system interface.
(14) There is no notice in advance if the indicator parameters change.