Used to measure ambient airCH4,co2andH2OAccurate, accurate and fast analyzer.
Features and advantages •CH4,co2andH2OSimultaneous measurement • Extremely wide linear measurement range •High specificity: Strong ability to resist cross-interference •Most advanced stability and accuracy •GL A331-GA AHigh-performance rack-type data drift lower • Quick measurement options (upper10Hz) •Install and run within minutes •Unparalleled reliability •Real-time diagnosis | ![]() |
ABB LG R-I cosBased on the long history and outstanding performance of Los Gatos Research analyzers, the gas analyzer uses patented off-axis integral cavity output spectroscopy (OA-ICOS) technology, the latest evolution of tunable diode laser absorption spectroscopy (TDLAS).
ABBGreenhouse gas analyzers are available in a variety of models and specifications, while monitoring methane, carbon dioxide and water vapor.3parameters.miniatureGL A131-GG Aand ultra-portableGL A132-GG AThe version is a compact, sturdy and easy to carry in the field, with enhanced performance (EP) Rack installationGL A331-GG ADesigned for additional accuracy, accuracy and stability.
With allLG R-I cosLike analyzers, greenhouse gas analyzers are simple to use and provide a wide dynamic range.It measures environmental levels with extremely high accuracy while at the same time50There is still inherent accuracy at concentrations of times.They are very strong and are ideal for long-term greenhouse gas monitoring, eddy current flux and soil flux research, and anywhere that requires fast and sensitive measurements.
GL A132-GG AData recording begins within 20 seconds after power-on.Therefore, users do not have to wait for a long warm-up time to balance the system.
ABBThe patented OA-ICOS technology is the fourth generation of optical cavity enhanced absorption technology.Compared with traditional fragile cavity decay spectroscopy technology and direct absorption technology, this technology has many advantages.The LGR-ICOS analyzer is simpler and more robust, providing users with higher performance and reliability while reducing operating costs.
GL A132-GG AThe analyzer comes with a built-in computer that stores data on an SD card almost indefinitely while sending real-time data to a tablet, smartphone or other WiFi device.
The analyzer includes control and analysis software.
parameter
Accuracy(1δ, 1 color / 10 color / 100 color):
CH4: 0.6 Screen Schedule / 0.2 Screen Schedule / 0.1 Screen Schedule
co2: 150 screening table / 50 screening table / 20 screening table
H2O: 150 ppm / 50 ppm / 17 ppm
Maximum drift
(15Minute average, inSTPOn, more thantwenty fourHour):
CH4:<3 screening table
co2:<0.2 ppm
Linear measurement range (when all technical indicators are met):
CH4:0-100 ppm(The external range is10000 ppm)
co2:0-20000 ppm
H2O:0-30000 ppm
Measurement speed:
0.01–1 Hz(User-selectable)
Highest10 HzHigh throughput options
Flow rate response:
<10Second(1 / Oh)
0.1Second(1 / Oh) (Use external dry scroll pumpACC-DS35hour)
Sampling conditions:
Operating temperature:5–45℃
Ambient humidity:<99%Relative humidity, no condensation
Data output:
WiFi,Ethernet,USB,MI Uconnect(8/16port),Serial (RS-232)
Power requirements:
110/240 vac,170 W(Stable state)
420 W(Using external dry scroll pumpACC-DP4Hhour)
size(HX WX D):
GL A331: 40 Smart (15.75 in.) Little 48 Smart (19 in.) Little 61 Smart (24 in.)
weight: 40 Viewed (88 Can't connect) - GL A331series