Measure in ambient airCH4,co2,coandH2OAccurate, accurate and fast analyzer.
Features and advantages •CH4,co2,coandH2OMeasurement simultaneously •The measurement rate can be selected, up to10 Hz • Extremely wide linear measurement range •High specificity: Strong ability to resist cross-interference •Most advanced stability and accuracy •Low drift is suitable for long-term monitoring • Quick response time option (shortest0.1Second) •Install and run within minutes •Unparalleled reliability •Real-time diagnosis | ![]() |
ABB LG R-I cosBased on the long history and outstanding performance of Los Gatos Research analyzers, the gas analyzer uses patented off-axis integral cavity output spectroscopy (OA-ICOS) technology, the latest evolution of tunable diode laser absorption spectroscopy (TDLAS).
ABBThe multi-gas carbon emission analyzer provides measurements of methane, carbon monoxide, carbon dioxide and water vapor. It uses a performance-enhanced rack architecture optimized for extremely high accuracy, accuracy, speed and stability while stillGood robustness, wide dynamic range (exceeding typical environmental levels10times the concentration),ABB OA-I cosThe principle design is very easy to use and low maintenance.
The overall performance and advantages of its unique design make it ideal for air quality research, greenhouse gas monitoring, high-precision soil flux research, and any place that requires fast, sensitive and reliable measurements, even in field research.
ABBThe patented OA-ICOS technology is the fourth generation of optical cavity enhanced absorption technology.Compared with traditional fragile cavity decay spectroscopy technology and direct absorption technology, this technology has many advantages.The LGR-ICOS analyzer is simpler and more robust, providing users with higher performance and reliability while reducing operating costs.
Multi-gas carbon emission analyzerEquipped with a built-in computer that stores data on an SD card almost indefinitely while sending real-time data to a tablet, smartphone or other WiFi device, the analyzer includes control and analysis software.
parameter
Accuracy(1δ, 1 color / 10 color / 100 color):
CH4: 3 screening table / 1 screening table / 0.3 screening table
co2: 0.2ppm / 0.07ppm / 0.02ppm
co: 0.07 ppm / 0.025 ppm / 0.02 ppm
H2O: 30 ppm / 9 ppm / 5 ppm
Maximum drift
(15Minute average, inSTPOn, more thantwenty fourHour):
CH4: 3 screen schedule
co2: 0.2 ppm
co : 0.1 ppm
Linear measurement range (when all technical indicators are met):
CH4:0-100 ppm
co:0-1000 ppm
co2:0-3000 ppm
H2O:0-30000 ppm
Operating range
CH4:0 - 0.1%
co:0 - 1%
co2:0 - 3%
H2O:0-30000 ppm
Measurement speed:
0.01–1 Hz(User-selectable)
Gundam10 HzHigh throughput options (limitedGL A331-GG A)
Flow rate response:
<12Second(1 / Oh)
0.1Second(1 / Oh) (Use external dry scroll pumpACC-DS35hour)
Sampling conditions:
Operating temperature:5–45℃
Ambient humidity:<99%Relative humidity, no condensation
Data output:
WiFi,Ethernet,USB,MI Uconnect(8/16port),Serial (RS-232)
Power requirements:
110/240 vac,170 W(Stable state)
size(HX WX D):
40 Smart (15.75 in.) Little 48 Smart (19 in.) Little 61 Smart (24 in.)
weight:40 Viewed (88 Can't connect)