In the public space, the detection of the new coronavirus in bioaerosols is divided into two parts: a portable aerosol sampler is used as a front-end collection device to sample air samples in the required places; then the collected samples are detected by using a nucleic acid amplification instrument.analyze.The handheld sampler developed by Anzhi Bio is combined with a fluorescence real-time detector, which is simple to operate and has a wide range of applications. It can achieve rapid collection and detection of new coronavirus in bioaerosols without nucleic acid extraction and P3 laboratories.
Handheld samplerHSP200
standard
"General Rules for Sampling and Analysis of Particle Bioaerosols in GB/T38517-2020"
"Technical Conditions of Particle Bioaerosol Samplers in GB/T39990-2021"
Features
Wet wall cyclone detection technology (impact method) sampling is adopted, and it complies with national standard methods
Small size, light weight, easy to carry, especially suitable for fast sampling on site
The collection process has large flow and short time
Easy to operate manually
Suitable for multi-site, multi-form (portable or mobile) bioaerosol collection
![]() |
Mobile robot multi-point air collection | Fixed air collection |
Specification
Standard
|
Consumables
Optional accessories Sampling bracket, model: TRIPOD | ![]() |
Constant temperature fluorescence real-time detector 1CT-208-16-YR Suitable for constant temperature amplification, detection and analysis of nucleic acid samples.It can be used in many fields such as public health, food safety, aquaculture diseases, pet infectious diseases, plant diseases, scientific research, etc.The inspection is fast, accurate and easy to operate, and is especially suitable for on-site inspection and use by grassroots personnel. principle The sample specifically amplifies the DNA fragment under constant temperature conditions in the detection hole. The amplified fragment is bound to the fluorescent dye, and when it is excited, a fluorescent signal is generated. This fluorescent signal is detected by a photodiode and processed by a microprocessor.Draw the amplification curve in real time and automatically judge the Yin-Yang results according to the built-in algorithm. performance
|
Temperature control
Module temperature control accuracy: no more than 0.5℃
Temperature accuracy: The absolute value of the measured value and the set temperature difference is not greater than 0,5℃
Module temperature uniformity: The temperature difference is within the range of 0.5℃
Specification
10.4-inch color touch screen
Dimensions: 210×302×200mm (length, width and height)
Rated voltage: 20V, 6A
External interface: RJ45, USB, WIF
Standard
Constant temperature fluorescence real-time detector: Model: ICT-208-16-YR
Consumables
Extraction-free reagents
Model: LC-N-100, 100 servings
Model: LC-N-500,500 servings
Origin: China