Aardvark Soil Infiltration Meter
Date:2017-04-22 15:10:10
Main functions





124.jpg

The principle of constant head, this instrument realizes automatic measurement of soil saturation water conductivity.In the field, the assembly can be completed in a very short time, and the water level drop rate can be automatically recorded. The stable state can be determined in a few minutes, and the constant drop rate can be calculated to obtain the saturated water conductivity.










Application areas








ComeResearch on water leakage in farmland

ComeStudy on spatial variation of soil infiltration characteristics

ComeResearch on the application of soil permeability in Yantian














Main technical parameters




125.jpg

ComeDiameter of soil drill: 10cm

ComeWater storage capacity: 8L

ComeMaximum supply water flow rate: 1000ml/min

ComeMeasuring depth: up to 15m

ComeUSB data meter:

UMaximum range: 10 Kg

UAccuracy: 0.2g (0.2ml)

UDimensions (L x W x H): 26.4 × 20.1 × 7.9 cm

UWeight 1.05 Kg (2.3 lbs.)

UPower consumption: 0.035 W

ComeRIF recorder:

UDimensions (L x W x H): 35.6 × 21.6 × 5.1 cm

UWeight: 1.65 Kg (3.6 lbs.)

UMaximum power consumption: 0.8 W

UBattery: Alkaline battery

ComeAdjustment unit:

UMaximum working range: 34 KPa (5 PSI)

UMinimum working range: 690 KPa (100 PSI)

UDimensions (OD x L): 7.6 x 31 cm

ComeShipping box size (L x W x H): 71 × 43 × 18 cm












Advantages









1.Soil saturation water conductivity can be measured at almost any depth

The depth that can be tested can range from the soil surface to 50 feet (about 16m) or deeper.

2.Easy to install and quickly obtain measurement results

Simply load the plastic container with water and the regulator is connected to the elastic tube - the installation is less than 15 minutes, and this regulator is connected to a high-quality tape measure, and the depth of the insertion can be seen through the tape measure at any time.With multiple measurement depths, it can be simpleLift up the tape measure and create a new head.

3.Directly measure moisture, the accuracy can reach 0.2ml
















Configuration Guide








blob.png





2840K1Manual measurement, manual data recording, maximum depth of measurement up to 10ft

2840K1PCAutomatic measurement, use a personal computer to record and store monitoring data, the maximum depth that can be measured is up to 10ft

2840K1RIFAutomatic measurement, using SEC's Flash Drive to record and store monitoring data, the maximum depth that can be measured up to 10ft

In addition, if you need to measure instruments with a depth of up to 50ft, you can order 2840K2, 2840K2PC, 2840K2RIF
















Optional:0237 D10l12Earth diamond set




blob.png














Origin:United States Soilmoisture Equipment Corp















Collection