Q-Box RP1LP low-range animal respiration measurement system
Date:2024-12-23 09:48:08

blob.png

Q-Box RP1LP low-range animal respiration measurement system is a system that uses an open circuit to measure animal respiration, used to measure small animals such as insects, reptiles, amphibians, other invertebrates and small mammals in open flow orMetabolic rate in a stop-flow gas exchange system.Can also be used to measure CO in fungal and microbial colonies2and O2exchange.Four measurement parameters can be monitored simultaneously, including oxygen, carbon dioxide, temperature and gas flow.

This system is suitable for teaching or scientific researchers to observe the oxygen consumption and carbon dioxide production of organisms in different environments. The oxygen sensor can be connected to a sealed sample chamber to calculate the metabolism of organisms by measuring the oxygen consumption rate.Rate.



Application areas

  • Comparison of metabolic rates of different organisms;

  • Determine the metabolic rate of organisms in sleep and different states;

  • Study the effect of temperature on metabolism;

  • Observe the effects of drugs and specific foods on metabolism;

  • Determine the rate of respiratory exchange of organisms when eating;

  • Determine the respiration of aquatic organisms;

  • Measure the respiration flux of microorganisms in the soil;

  • Determine the respiration effect of plant roots

blob.png



When combined with the Gas Switching System (GSS), breathing rate and RQ measurements can be performed on up to seven organisms, including the referenced 8-channel system.


Øgas switching system (GS S)

The GSS gas exchange system works with Q-BOX to measure gas exchange from multiple samples.Makes the gas exchange system allow monitoring of up to 8 different channels using a single Q-Box system, such as the Q-Box RP1LP low-range breathing package, the Q-Box RP2LP high-range breathing package, and the use of the Q-Box NF1LP nitrogen fixation package and Q-The Box CO650 Plant CO2 Analysis Package monitors up to 4 different samples.The GSS gas conversion system allows multi-channel measurement of respiration (VO2 and VCO2), nitrogen fixation, photosynthesis and transpiration.


blob.png

8-channel closed-flow system

blob.png

8-channel open flow system


Other components

(1) Q-S151Carbon dioxide analyzer


blob.png



The Q-S151 infrared carbon dioxide analyzer is a non-dispersive infrared carbon dioxide analyzer with a measurement range of 0-2000ppm and a resolution of 1ppm.Reliable and robust technology and modular design, easy to install in our Q-Box measurement system or use independently.Q-S151 is ideal for determining CO2 exchange in leaves, insects, small animals, or organisms with low metabolic rates.It is also well used in field and laboratory soil respiration activity assays.


ComeShouldco2Analyzers can be used in flow system configurations for instantaneous and continuous measurementsco2Production or consumption.It can also be used for measurement of extremely low activity levels in closed system mode.

ComeQ-S151 co2The analyzer can be set to use in injection mode, in which a small amount of CO is placed2Gas sample injection flows through CO2In the carrier gas of the sensor, to measure CO in the headspace of the collected sample2level.

ComeQ-S15yesQ-BOX systemKey components of carbon dioxide control for regulating growthroomOr indoor pCO2.


Main features

ComeThe switchable range is0–500 ppm and 0–2000 ppm CO2

ComeCarbon dioxide resolution:1 ppmDigital display

ComeNon-dispersive infrared technology

ComeModulation infrared light source= No moving parts

ComeSetting under two ranges0–5 V analog output

ComeOptional battery packs for on-site use

ComeSmall and portable


Technical Specifications

blob.png

blob.png


(2)Q-S102 O2Analyzer

blob.png

Q-S102 O2Analyzer is configured to measure O flowing through a gas exchange system in the range of 0-25% or 0-100%2Concentration, accuracy is 0.21%.It is to determine the high metabolic rate in the open flow system structure of O2Ideal instrument for ingestion.For organisms with low metabolic rates, it can be used in closed flow systems, where the absorption rate of O2 can be determined by O in the system2The slope of the drop is calculated.O2The analyzer also includes an air pressure sensor for measuring the total air pressure of the oxygen sensor.


ØMain features

ComeQ-S102 is Q-BoxsystemKey components, its power supply system isThe primary battery (lead-oxygen battery) consists of a lead anode, an oxygen cathode and an acidic electrolyte.It also includes an oxygen permeable polytetrafluoroethylene FEP film bound to its surface with a gold electrode.The oxygen diffused through the membrane is electrochemically reduced on the gold electrode.Resistors and thermistors (for temperature compensation) are connected between the anode and the cathode.The output of the instrument is related to the current flowing through the resistor and thermistorproportional, in contact with polytetrafluoroethylene filmPO2In proportional.

ComeQ-S102 O2Analyzer Q-S102 O2The analyzer requires a data interface and operation software with two analog signal ports.We recommend the C610 LabQuest mini data interface using the C901 Logger Pro software.


ØTechnical Specifications

blob.png


(3)Q-P103 air pump


blob.pngblob.png

The Q-P103 air pump is a diaphragm pump that can produce gas flow up to 1L/min.Rubber feet and internal rubber pump bracket ensure quiet operation.The Luer gas inlet and outlet can be conveniently connected to any gas exchange system.

Potentiometer can accurately control the pump speed from50%-100%, reducing the risk of unexpected changes.The gas flow can be adjusted through the two needle valves on the back of the instrument.Internal outlet laminar flow damping volume ensures pressure pulse damping for laminar flow mass flow sensors



ØTechnical Specifications

power supply:12VD C, 215MA

Maximum pressure1.8 PS IG

Maximum vacuum:3.7 HG

Maximum gas flow rate (no load):1l/civil

size(clever):(H x width x depth: 5.5 to 9.5 x 9.5 x 17)

weight(): 900

Material: Metal

Warranty period:1 year

Q-P651Air pump (optional)

Airflow pump (3L/min without load)

power supplyDC 12V, 315mA

Maximum pressure15PS IG

size(Also /me /) smart5.5~9.5/9.5/17

weight900


(4)Q-G266Flowmeter


blob.png

The Q-G266 flow monitor is a gas flow monitor suitable for measuring and tracking continuous flows in the range of 0 to 1L/min.Gas can be supplied from a pump or pressurized source to the stainless steel luer input port of the device.The Q-G266 flow monitor is calibrated at the factory to measure the mass flow of gas.Each device provides specific calibration values.The gas flow can be controlled manually by the stainless steel needle valve on the back of the instrument.


This flow monitor can be used asQ-Box CO650 Plant CO2Analytical package and components of Q-Box SR1LP soil breathing package, Q-Box RP1LP low range breathing package and Q-Box HR1LP human breathing package.

To monitor gas flow,The Q-G266 needs to be used with a data acquisition interface (i.e., C610 LabQuest Mini) and software (such as the C901 Logger Pro software) or any other data acquisition software that accepts 0–5 V analog signals.


ØTechnical Specifications

blob.png


(5)C610 lab quest mini


blob.png

The C610 LabQuest Mini is a powerful, affordable, easy-to-use sensor data acquisition interface for computer-based data acquisition on PC or Macintosh computers.The C610 LabQuest Mini works with the C901 LoggerPro software to collect data from any Qubit sensor at a sampling rate of 100khz.The C610 LabQuest Mini can also be used with a digital control unit (DCU) to control instruments or sensors (on/off).


This fast sampling, compact and easy-to-use data interface is ideal for use with all qubit sensors.

Computer connection: USB 2.0 full speed

Maximum sampling rate: per second100,000 samples

Analog input:3

Digital input:2

size:10.5 x 8.5 x 2.6 cm

Warranty period:5 years


(6)software


blob.png

Open flow system

blob.png

Closed flow system


Other componentsTechnical Specifications

blob.png


Optional sample room

blob.png

Origin: Canada