CN802 carbon and nitrogen element analyzer
Date:2024-12-20 11:08:27

cn802Carbon and nitrogen element analyzer



image.png

image.png


image.png


NDA 702/cn802–Automatic injection


Electric sample injector

Standard configuration:1indivual30Position injection plate

Maximum injection number:

Additional3A sample tray:117A sample

NDA 702/cn 802The automatic sampler transfers the sample to the combustion furnace through the following steps:

The purge chamber is filled with carrier gas

Oxygen enters the combustion tube

The effect of gravity through the sample enters the combustion chamber

Overall, the sample falls into the purge chamber, pops up and enters the combustion chamber, and the injection system is closed

image.png


Burning furnace


In order to fully burn organic samples, high temperatures are necessary, generally higher than 900℃


NDA/cnBurning furnace:

•Maximum temperature: 1100 °C

•reliable

•Safety

•Long service life

• Less maintenance

image.png


VE LPReaction tube


Reaction tubes are used for combustion and reduction

→ Two materials: quartz and metal

image.png

image.png


Combustion reaction tube


Combustion in an oxygen-rich environment converts organic samples into their elemental compounds:

O2, N2, NOx, co2, H2O, co, so3…

The combustion reaction tube is prepared or prefilled reaction tube is selected as follows (code A0000158)

Combustion reaction

image.png


Combustion tube –Ash collection


The ash produced by the combustion is collected in a dedicated ash collection tube.

start-up kitThree versions are included to select the best version according to customer needs


image.png


Metal ash collection tube


benefit


Reusable 5/6 times (600/700 analysis)*

Lower cost per sample

Excellent high temperature resistance and damage resistance

Cleaning kits are used as an accessory for daily maintenance and last longer

image.pngimage.png


High-strength samples-Save life


Sausages, soy sauce, plants and soil, etc. contain salt(halogen)The sample will corrode the metal tube.This is due to the formation ofHClCorroded metal parts.

When using such samples, it is essential to regularly clean pipes and other metal parts, as corrosion can reduce the life of metal consumables.


how to do IT?

Keep sample volume to a minimum

If possible,2The root tube is constantly cleaned alternately

image.png


Restore tube

Reducer - vcopperTM

The gas passes through a reduction furnace, where:

•Nitrogen oxide is reduced to N2 molecules

• CO conversion to CO2

:The exclusive Vcopper high-reducing effector provides unique properties in the following aspects:

•Life life: up to 750* analysis

•Convenience: It frees users from tedious work, and replaces consumables, etc. very fast.

Pre-installed reaction tubes (quartz only) are available

image.png

H2OSeparation

VE LP ND AIt has two water removal units with CN series.

WT1 D-Day step

•This physical water removal unit is a VELP-exclusive water removal unit located between the combustion furnace and the reduction furnace.

•99% moisture is removed at this step

•Maintenance-free

•Reduce individual sample costs and reduce reducing agent consumption

WT2

• Chemical desiccant, easy to obtain

co2Separation

VE LPElement analyzers use unique trap regeneration technology.

Specific absorbents, microporous materials, continuously perform the adsorption and desorption of carbon dioxide to achieve its own regeneration.

A/BTwo cavity work alternately

cn802Infrared detector

VE LPA dedicated (non-dispersive infrared) NDIR detector is able to read the carbon dioxide content and send information to CNSoft.

Read only CO2 wavelength: 4.3μm

•Selective detector

•High accuracy and precision

•Read only C content

•Maintenance-free

•LOD: 0.01 mg C (absolute value)

•Maximum C content: 150mg (absolute value)


TCD (thermal conductivity detector) detects elemental nitrogen N2.The data is sent to the PC and recorded through software.

VELP LoGas TCD delivers excellent performance

•NDA 702/CN802 – Lowest N element LOD:

•he: 0,001 Buy N

•AR: 0,01 Buy N

•Low gas consumption, save 50% immediately

•Excellent reliability

•Extra-long service life


TCD (thermal conductivity detector) detects elemental nitrogen N2.The data is sent to the PC and recorded through software.

VELP LoGas TCD delivers excellent performance

•NDA 702/CN802 – Lowest N element LOD:

•he: 0,001 Buy N

•AR: 0,01 Buy N

•Low gas consumption, save 50% immediately

•Excellent reliability

•Extra-long service life

image.png

All useful information in one window

Create, save and call databases(.xls,.CSV,.txt, .PDFwait)

Customized test report

Create and manage different calibration curves

Different nitrogen standards can be used

Recalculate and reintegrate functions

The results can be found in different measurement units

• Method library is suitable for many types of samples to minimize analysis costs

• Automatic leak testing for complete system

•Daily control and maintenance

•Real-time check of instrument status

Repeatability(RSD): <0.5% for EDTA standard (9.57% N)

Recovery rate: > 99.5% N

Detection limit: 0.001 every n absolute (he)

0.01 Buy N (AR)

The required gas

Helium(he): purity 99.999% (grade 5.0)

Argon(AR): purity 99.999% (grade 5.0)

oxygen(O2): purity 99.999% (grade 5.0)

image.png


NDA 702– Summary


cn softcalibration

•many/Single point calibration

•CalibrateableCandNparameter

• Create and manage different calibration curves

• Specify the name function of the calibration curve

•Manage different standard curves

•Recalculate and reintegrate functions

image.png

n softAnalysis results

FromIRandTCDSensor data reaches powerfulcn soft, providing state-of-the-art performance:

•All useful information in one window

C/NCompared to automatic calculation

•Complete pre-installation method library

•Create, save and call databases(.XML,.CSV,.txtwait)

•Create and export test reports in multiple formats(l IMS, PDF, CSV, txt,…)

•Leak Test Management(By region or complete)

•Select one or more analyses to allowcn soft TMShow all related peaks.

•Click the Carbon or Nitrogen Peak box to open it in full window mode



image.png


image.png


image.png



Innovation in fully automatic carbon and nitrogen measurementVE LPSolution:

•Easy to use:Easy and easy to operate

• Rapid analysis:Just3/4Detected in minutesNandC

•Multifunctional:UniquecnAnalyzer andheandARWork seamlessly

•Meet any sample test quantity requirement:most117Sample

•precise:Comply with major international standards

•Durable:Decades of design work

•reliable:Easy to maintain, throughVE LP er MESEnhanced service support

•Cloud platform connection instrument:passVE LP er MESOperator monitoring and controlcn 802, and access its data anytime, anywhere.

C/NImportance in Agriculture and Environment

soil

Elemental analysis provides important information about biological processes and nutrient supply for selective fertilization of agricultural land.

The following two are very critical:

•The ratio of carbon to nitrogen, that is, the carbon to nitrogen ratio, is used to determine whether the balance of elements in the soil is correct.

•Soil organic layer related to crop growth

fertilizer

Carbon-nitrogen ratio is of great significance to correct land fertilization


image.png


image.png


image.png


image.png

image.png


image.png


image.png



Origin: Italy VELP



Collection