Precise, accurate and durable analyzer for measuring soilNH3,CH4andco2
Features and advantages NH3,CH4,co2andH2OSimultaneous measurement Measurement rate can be selected, up to1 Hz Extremely wide dynamics/Linear range Highly specific: strong ability to resist cross-interference State-of-the-art stability and accuracy Install and run within minutes Unparalleled reliability Real-time diagnosis | ![]() |
ABB LG R-I cosBased on the long history and outstanding performance of Los Gatos Research analyzers, the gas analyzer uses patented off-axis integral cavity output spectroscopy (OA-ICOS) technology, the latest evolution of tunable diode laser absorption spectroscopy (TDLAS).
ABBThe soil gas analyzer simultaneously reports parameters such as ammonia, methane, carbon dioxide and water vapor in a compact, robust and portable analyzer.
With allLG R-I cosLike the analyzer, the soil flux gas analyzer is simple to use and has a very wide dynamic range.GL A132-so FX1MeasurementbrandLevel, at the same time10The typical environmental level is still linear.GL A132-so FX2Still providing single digitsScreening tableAccuracy, but can be measured in agricultural environments250ppmofNH3.They are all very strong, which makes them ideal for field research, air quality research and soil flux research, and where precise measurements are required.
GL A132-so FXData recording begins within 20 seconds after power-on.Therefore, users do not have to wait for a long warm-up time to balance the system.
ABBThe patented OA-ICOS technology is the fourth generation of optical cavity enhanced absorption technology.Compared with traditional fragile cavity decay spectroscopy technology and direct absorption technology, this technology has many advantages.The LGR-ICOS analyzer is simpler and more robust, providing users with higher performance and reliability while reducing operating costs.
GL A132-so FXSoil gas analyzerEquipped with a built-in computer that stores data on an SD card almost indefinitely while sending real-time data to a tablet, smartphone or other WiFi device.
parameter:
Accuracy (1σ,1 is/10 is/100 is):
so FX1
NH3:2 film schedule / 0.6 film schedule / 0.2 film schedule
CH4:2 film schedule / 0.6 film schedule / 0.2 film schedule
co2:2.25 ppm / 0.75 ppm / 0.25 ppm
H2O: H2 O: 300 ppm / 100 ppm / 30 ppm
so FX2
NH3:10 screening table / 3.5 screening table / 1.5 screening table @ 10ppm
NH3:20 screening table / 7 screening table / 2.5 screening table @ 200ppm
CH4:4 film schedule / 1.3 film schedule / 0.5 film schedule
co2:5 ppm / 1.5 ppm / 0.5 ppm
H2O: 4.5 ppm / 1.5 ppm / 0.5 ppm
Linear measurement range:
so FX1 NH3:0–10 ppm
so FX2 NH3:0–250 ppm
CH4:0–100ppm
co2:0–20000 ppm
H2O:0–30000 ppm
Operating range:
so FX1 NH3:0–200 ppm
so FX2 NH3:0–1000 ppm
co2:0–3%
CH4:0–500ppm
Sampling conditions:
Sampling gas temperature: -40–50°C
Equipment operating temperature: 5–45°C
Ambient humidity: relative humidity 0-99%, no condensation
Traffic time response: less than 8 seconds (1/e)
Data output
WiFi, Ethernet,USB,MI Uconnect(8ports), serial (RS-232)
66WCharger unit
60W 11-30VDC power supply
size:
18 SmartHigh ×47 SmartWide ×36 Smartdeep
7″H×18.5″W×14″D
weight:16.9 Viewed