GLA132-SOFX portable soil gas analyzer
Date:2024-12-20 11:04:56

Precise, accurate and durable analyzer for measuring soilNH3,CH4andco2


Features and advantages

NH3,CH4,co2andH2OSimultaneous measurement

Measurement rate can be selected, up to1 Hz

Extremely wide dynamics/Linear range

Highly specific: strong ability to resist cross-interference

State-of-the-art stability and accuracy

Install and run within minutes

Unparalleled reliability

Real-time diagnosis

image.png


ABB LG R-I cosBased on the long history and outstanding performance of Los Gatos Research analyzers, the gas analyzer uses patented off-axis integral cavity output spectroscopy (OA-ICOS) technology, the latest evolution of tunable diode laser absorption spectroscopy (TDLAS).

ABBThe soil gas analyzer simultaneously reports parameters such as ammonia, methane, carbon dioxide and water vapor in a compact, robust and portable analyzer.

With allLG R-I cosLike the analyzer, the soil flux gas analyzer is simple to use and has a very wide dynamic range.GL A132-so FX1MeasurementbrandLevel, at the same time10The typical environmental level is still linear.GL A132-so FX2Still providing single digitsScreening tableAccuracy, but can be measured in agricultural environments250ppmofNH3.They are all very strong, which makes them ideal for field research, air quality research and soil flux research, and where precise measurements are required.


GL A132-so FXData recording begins within 20 seconds after power-on.Therefore, users do not have to wait for a long warm-up time to balance the system.

ABBThe patented OA-ICOS technology is the fourth generation of optical cavity enhanced absorption technology.Compared with traditional fragile cavity decay spectroscopy technology and direct absorption technology, this technology has many advantages.The LGR-ICOS analyzer is simpler and more robust, providing users with higher performance and reliability while reducing operating costs.


GL A132-so FXSoil gas analyzerEquipped with a built-in computer that stores data on an SD card almost indefinitely while sending real-time data to a tablet, smartphone or other WiFi device.


parameter:

Accuracy (1σ,1 is/10 is/100 is):

so FX1

NH3:2 film schedule / 0.6 film schedule / 0.2 film schedule

CH4:2 film schedule / 0.6 film schedule / 0.2 film schedule

co2:2.25 ppm / 0.75 ppm / 0.25 ppm

H2O: H2 O: 300 ppm / 100 ppm / 30 ppm

so FX2

NH3:10 screening table / 3.5 screening table / 1.5 screening table @ 10ppm

NH3:20 screening table / 7 screening table / 2.5 screening table @ 200ppm

CH4:4 film schedule / 1.3 film schedule / 0.5 film schedule

co2:5 ppm / 1.5 ppm / 0.5 ppm

H2O: 4.5 ppm / 1.5 ppm / 0.5 ppm

Linear measurement range:

so FX1 NH3:010 ppm

so FX2 NH3:0250 ppm

CH4:0100ppm

co2:020000 ppm

H2O:030000 ppm

Operating range:

so FX1 NH3:0200 ppm

so FX2 NH3:01000 ppm

co2:03%

CH4:0500ppm

Sampling conditions:

Sampling gas temperature: -40–50°C

Equipment operating temperature: 5–45°C

Ambient humidity: relative humidity 0-99%, no condensation

Traffic time response: less than 8 seconds (1/e)

Data output
WiFi, Ethernet,USB,MI Uconnect(8ports), serial (RS-232)

66WCharger unit

60W 11-30VDC power supply

size:

18 SmartHigh ×47 SmartWide ×36 Smartdeep

7H×18.5W×14D

weight:16.9 Viewed





Collection