Multifunctional gas analyzer——gas era one pulse
A multifunctional gas monitoring solution with first-class performance and flexible use
The GASERA ONE PULSE configuration is suitable for multiple application scenarios, with one instrument measuring up to 9 gases and H2O (water vapor).The gas can be selectively measured by selecting an optical filter with a narrow spectrum band for both the target and the interfering gas.
Advanced Multi-Composition Analysis:
Unique analytical method to analyze each gas composition with minimal cross sensitivity
The stoichiometric minimum square fitting based on sample response and calibration data displays analysis results, providing unparalleled selection specificity.
Optional configuration:
Multi-point injector: Enhance monitoring capabilities by increasing the number of sample inlets to 12.Additionally, it can perform automatic sampling from multiple points.
Core Technology:
The core "engine" is based on the combination of ultra-sensitive cantilever beam enhanced photoacoustic detection technology with broadband infrared sources and narrowband pass filters.This unique approach ensures stable and reliable operation with high sensitivity and wide dynamic range.The GASERA ONE PULSE is designed to measure the trace amount of almost any gas that absorbs infrared light.
System Features:
üAnalyze multiple gases simultaneously
üDetection limits from ppb to sub-ppm
üUsers can configure response time of 15 seconds to several minutes
üWide dynamic range, stable operation
üNo consumables
üSmall sample size, a few milliliters (mL)
üBuilt-in gas exchange system
üMaintenance calibration cycle 12 months
üUser-configurable monitoring tasks
üIntuitive user interface
üBuilt-in display displays results digitally and graphically
üThe air chamber is stable at 50°C and 850 mbar, which can avoid drift due to changes in environmental conditions.
Application areas:
üLivestock: Monitoring livestock, individual animal emissions and air quality in animal shelters
üFume hood performance test: Use SF6Fume hood leak test
üGreenhouse gas research: In situ measurement of greenhouse gas emissions in air, soil and water, assessing climate impacts
üOccupational Health and Safety: Measuring toxic gas leaks in the industry
üPhotocatalysis: Measurement of several gases in the performance evaluation of photocatalytic equipment
üRefrigerant Leaks: Monitoring Refrigerant Leaks in HVAC Systems
üsf6Leakage: SF in power facilities and switchgear manufacturing6Leak detection
üSoil analysis: Soil caused by fertilization N2O and NH3Emission Assessment
üTracer gas: Use tracer gas to measure air exchange
üWaste anesthetic gases: Monitor the levels of anesthetic gases in hospital operating rooms, such as fluorine and N2
Measure gas:
üAnesthetics: deflurane, amphiroth, isoflurane, sevoflurane, etc.
üGreenhouse gases: CF4, C2F6, R13, R-134, co2, N2O etc.
üTracer gas: SF6, R-134, HF O-1234 month
üHydrocarbons: CH4, C2H2, C2H4, C2H6wait
üInorganic substances: CO, CO2, H2O, N2O, NF3, NH3, sf6, so2
üVOCs: acetone, benzene, ethanol, formaldehyde, methanol, toluene, xylene, etc.
Main technical parameters:
General technical parameters
ü19” 3U (unit) enclosure for desktop and rack mounting operations
üDimensions: 48.4 x 13.9 x 44cm (W x He x Depth)
üWeight: about 13 kg
üBuilt-in computer with 7-inch WSVGA display
üData storage capacity is sufficient for continuous monitoring at least 1 year with the shortest sampling interval
üTotal internal gas volume 30 ml
üThere are 2 gas-channel interfaces including 2 sample input connections, equipped with user-replaceable dust and small particulate filters
üElectrical connection: Input voltage: 90-264 Vac, 47-63 Hz; Input power: Maximum 75 W
üInterface: Ethernet, USB or other options
üvia USB serial, current message or voltage message.Supports MODBUS and AK protocols
Operation and storage environment parameters
üOperating conditions: Temperature range: 0-40℃; Humidity: less than 90%, no condensation; Pressure range: ambient level; Dust/waterproof: IP20 (IEC 529)
üStorage conditions: Temperature range: -20-60℃
üSample gas conditions: Temperature: 0-49℃; Humidity: No condensation, maximum relative humidity 80% (temperature up to 35℃), linearly dropping to 35% relative humidity; Pressure: 750-1050 mbar; Gas flow: Approximately 0.6 liters/min during gas exchange.The gas exchange parameters can be configured by the user; < 1 μm particulate matter.
Measure relevant technical parameters
üResponse time: 15 seconds to several minutes, depending on the user-configurable channel integration time (C.I.T.) and gas exchange program
üDetection limit: Depend on gas and light source, usually from sub-ppb to sub-ppm
üDynamic range: usually 5 orders of magnitude (i.e. 100,000 times the detection limit)
üRepeatability: less than 1% of the measured value under operating conditions of calibration concentration
üAccuracy: Limited by the accuracy of calibration gas at calibration concentrations.Typically 2–5 %
üTemperature stability: Ambient temperature changes in the operating temperature range will not cause drift
üPressure stability: The sample gas pressure changes within the pressure range will not cause drift
Origin: Gasera, Finland