Air temperature Principle: NTC Range: –50…60°C Accuracy: ± 0.2°C (–20°C…+50°C), the remaining ± 0.5°C (>–30°C) Relative humidity Principle: Capacitor Range: 0…100% RH Accuracy: ±2%RH Total solar radiation Response time (95%): <1s Spectral range: 300 to 1100nm Range: 0 to 1400W/m² Accuracy: 5% Air pressure Principle: MEMS capacitor Range: 300…1200hPa Accuracy: ±0.5hPa (0…+40°C) wind direction Principle: Ultrasonic Range: 0…359.9° Accuracy: <3°, RMSE>1.0m/s Wind speed Principle: Ultrasonic Range: 0…90m/s Accuracy: ±0.2m/s or ±2%RMS, the larger one (0...65m/s), the remaining ±5% Technical parameters Specifications: Approximately Ø150mm, height 377mm Weight: about 1.5kg Heating: 20VA 24VDC Protection level: IP66 Data interface: RS485, 2-wire, half-duplex Power consumption: 4...32VDC Working humidity: 0…100% Operating temperature: –50…60 °C appendix Surge protection device Power supply 24V/4A UMB communication interface converter ISOCON-UMB Analog to digital signal converter DACON8-UMB Surface temperature sensor WT1 Pavement temperature sensor WST1 Rainfall barrel WTB100 20m cable (10m is standard, if you need 20m, please select this item) Place of origin German Lufft | ![]() |