Air temperature Principle: NTC negative temperature coefficient thermistor Measurement range: -50…60°C Unit: °C; °F Accuracy: ±0.2°C (-20…50°C), others: ±0.5°C (>-30°C) Relative humidity Principle: Capacitive Measurement range: 0…100 % RH Unit: % RH; g/m³; g/kg Accuracy: ±2 % RH Air pressure Principle: MEMS capacitive Measurement range: 300…1200 hPa Unit: ±0.5hPa Accuracy: ±0.1 hPa (0 … +40°C) Precipitation Resolution: 0.01 mm Repeatability: Standard > 90% Measurement range: raindrop size 0.3…5.0mm Precipitation type: rain or snow Technical parameters Protection level: IP66 Specifications: 150 mm in diameter, 280 mm in height Weight: 2Kg Interface: RS485, dual-wire connection method, half-duplex Power supply: 24VDC±10% (without heating) Operating temperature: -50…60°C Working humidity: 0…100% RH Heating power: 20VA@24VDC Cable length: 10 m Accessories Surge protector P Power supply 24V/4A UMB Interface Converter ISOCON Digital-to-analog converter DACON8-UMB Temperature sensor WT1 Pavement temperature sensor WST1 Connection cable 20m Place of origin German Lufft | ![]() |